Skip to product information
1 of 6

Pipe Couplers For Multiple Commercial and Residential Installation and Repair Applications

Pipe Couplers For Multiple Commercial and Residential Installation and Repair Applications

Regular price $26.85 USD
Regular price
RETAIL PRICE
$34.99 USD
Sale price $26.85 USD
Sale Sold out

GS1: 316867054683

Shopify Product Page

This is a special order item.

Shopify Product Page


In-Stock Orders Will Ship Within
Hours
Minutes
Seconds

HOURS

MINUTES

SECONDS

View full details
Dektite Flexible Couplers/Joiners For Various Piping Applications

See Descriptions of the Different Styles and Applications Below
Dimensions based on Outside diameter of the pipe (i.e. 6") Coupling ID is Inside dimension of Coupler

Call Customer Service at 406-752-5253 to Inquire About Quantity Discounts

✔DEKS / Joiners Pipe Couplers For Multiple Commercial and Residential Leak Proof Pipe Connections For Multiple Applications
✔Include and Are Not Limited to Household Sewer, Drain, Waste and Vent Piping But Also Retrofit Repairs, Roof Drains and Cut-Ins
✔Resistant To Chemicals, Ultraviolet Rays, Sewer Gas and Fungus Growth and Root Resistant
✔Designed To Connect Many Different Pipe Materials - Hub and Non-Hub Pipe


Reasons why shielded couplings are important: (1) Shear forces: Shielded couplings are made with a heavy-duty shear ring that helps the pipeline withstand shear forces and tensile stressing. (2) Pipe alignment: Shielded couplings help keep pipe alignment. Protection from ground pressures: (3) Shielded couplings are encased in a metal structure (shear ring) that protects them from the grounds surrounding pressures. (4) Cost savings: Shielded couplings can help eliminate costly repairs (5) Ease of installation: Shielded couplings can be easier to install because they require fewer stainless steel bands, which reduces the amount of tightening time.

Product Information Link Available Here

Installation Video  See Here

DX 1002 - Flexible Couplings. For Connecting Clay Pipe to Clay Pipe or Plastic (PVC).
For Non-Pressure Drain, Waste and Vent Pipe Only. For Connecting Clay to Clay and Plastic. The Flexible Coupler has been engineered to provide a leak proof seal connection on many pipe materials. Flexible Couplings provide a high quality and user friendly installation. Applications include, but are not limited to sewer and in house connections: seals against infiltration and exfiltration, drain, waste, vent piping, house to main, retrofit,repairs, roof drains and cut ins. The compounds utilized to manufacture will provide long-term installed life and are not affected by soil. Meets ASTM C1173 - Meets ASTM D5926 - Meets CISPI 310 UPC / IAPMO File 5014 - Meets CSA B 602

DX156 Flexible Couplings. For Connecting Clay, Plastic, Copper or Steel to Clay, Plastic, Copper, Steel or Lead Pipes
The Flexible Coupler has been engineered to provide a leak proof seal connection on many pipe materials. Flexible Couplings provide a high quality and user friendly installation. Applications include, but are not limited to sewer and in house connections: seals against infiltration and exfiltration, drain, waste, vent piping, house to main, retrofit,repairs, roof drains and cut ins. The compounds utilized to manufacture will provide long-term installed life and are not affected by soil. Meets ASTM C1173 - Meets ASTM D5926 - Meets CISPI 310 UPC / IAPMO File 5014 - Meets CSA B 602

DX1002 SR Couplers (Stainless Steel Non-Shear With 4 Gear Bands) . For Connecting Clay Pipe to Clay or Plastic Pipe (PVC)
The gasket is manufactured from virgin compound in which the primary elastomer is polychloroprene (neoprene). Engineered to join Cast Iron pipe, PVC., Steel, Copper, and tubular drain waste and vent systems. Horizontal pipe and fittings must be installed / properly braced per Chapter IV,Handbook Cast Iron Soil Pipe Institute to prevent movement or joint separation. Meets ASTM C 564 - Meets CISPI 310 - Meets ASTM C1460 UPC / IAPMO File #6525 - Meets CSA B 602

DX1056 SR Couplers (SS Non-Shear Shield with 4 Gear Bands) For Connecting Clay, Plastic, Copper, Steel or Lead to Clay, Plastic, Copper, Steel or Lead
For Non-Pressure Drain, Waste and Vent Pipes Only. The gasket is manufactured from virgin compound in which the primary elastomer is polychloroprene (neoprene). These couplings consist of a 301 stainless shield in conjunction with stainless steel clamps, secured in place by means of an affixed and floating eyelet to allow the clamps movement during tightening, allowing the band and shield to move independently. The stainless steel shield and clamps are corrosion resistant. Heavy Duty SS Shielded Coupling has been engineered join Cast Iron pipe, PVC., Steel, Copper, and tubular drain waste and vent systems. Horizontal pipe and fittings must be installed / properly braced per Chapter IV, Handbook Cast Iron Soil Pipe Institute to prevent movement or joint separation. Meets ASTM C 564 - Meets ASTM C 1277 - Meets CISPI 310 (ASTM A 888) - Meets CSA B 60 UPC / IAPMO File #4936

DXNH Stainless Steel No Hub Couplers
The gasket is manufactured from a properly vulcanized virgin compound in which the primary elastomer is polychloroprene(Neoprene). Heavy Duty SS No Hub Coupling has been engineered to provide a heavy duty, all stainless steel coupling, fulfilling the desire for a more rigid joint with the need to provide a superior sound seal, which can accommodate possible disparities in the mating of No Hub pipe and fittings. This has been accomplished by manufacturing our coupling with a heavy duty corrugated shield of ample width to accommodate additional surface bearing sealing clamps. The additional sealing clamps when torqued to 80 inch pounds, offer two important performance related installation benefits. First, the overall dimensional thickness of the clamp and shield, in conjunction with the additional width of the coupling result in a more uniformly rigid joint, with the load being supported at both the outer edge of the coupling and the centerline of the joint. Second, the additional sealing clamps provide increased surface bearing contact between the coupling and the pipe or fittings, thereby inhibiting joint movement at higher internal pressures
Meets ASTM C 564 - Meets ASTM C 1540 - Meets CISPI 310 - Meets FM 1680 Class 1 - Meets CSA B 60 IAPMO File 6525